IT認証試験問題集
GOWUKAKU|IT認定資格の最新の試験問題集(PDF版・無料サンプル問題)を提供しています
 ホームページ / NetApp 問題集 / NS0-593 問題集  / NS0-593 問題練習

NetApp NS0-593 問題練習

NetApp Certified Support Engineer ONTAP Specialist 試験

最終更新日: 2026/10/14  収録内容確認済 | PDF問題集: 全 65 問収録

【仕様案内】:NS0-593 問題集(PDF版)は日本語版&英語版の2言語セットに対応しております(日本語版が準備中の科目は英語版を即時ダウンロードのうえ、日本語版は準備完了次第ご登録メールへ自動送付いたします)。

本ページでは問題集の無料サンプル問題を公開しており、出題形式や現在の理解度を確認することができます。

全65問を収録したPDF版は、NS0-593 問題集からご確認いただけます。

 / 2

Question No : 1
Your customer wants to access a LUN on a FAS 8300 system from a VMware ESXi server through the FC protocol. They already created a new SVM, volume. LUN, and igroup for this purpose. The customer reports that the server's FC HBA port Is online, but the LUN does not show up.

image006.png

Referring to the exhibit, what is the reason for this problem?

正解:

Question No : 2
You are attempting to connect a NetApp ONTAP cluster to a very complex network that requires LIFs to fail over across subnets.
How would youaccomplish this task?

正解:

Question No : 3
You receive the panic message shown in the exhibit.

image005.png

In this scenario, which component should you troubleshoot first?

正解:

Question No : 4
Your customer complains about missing volume snapshot copies on a SnapMlrror destination. While investigating this case, you notice an executed SnapMirror resync operation in the event logs of the system.
In this scenario, what Is the cause of this problem?

正解:

Question No : 5
Your customer has deployed a two petabyte NetAppONTAP FlexGroup volume across their 4-node ONIAP 9.8 cluster. They plan to store over three billion files. They want to prevent file 10 conflicts since files are placed into the FlexGroup volume.
In this scenario, which two NFS SVM parameters should be enabled? (Choose two.)

正解:

Question No : 6
Referring to the exhibit, what do you need to do to return the MetroCluster to a normal state?

image004.png

A. Enter the metroclustor switchback command on Site B.
B. Enter the metrocluster switchback command on Site A.
C. Enter the storage failover giveback command on Site B.
D. Enter the storage failover giveback command on Site A.

正解: B

Question No : 7
Your customer added a new DS4246 shelf to their FAS2750 single-node system and created a new aggregate on the new shelf. Two weeks later, they log into Active IQ and discover the Medium Impact error shown below.
Shelves with both connections via the same SAS path detected

image003.png

Referring to the exhibit, which statement is correct?

正解:

Question No : 8
The motherboard of Node-01 is being replaced. To perform this task, a takeover was Initiated from Node-02. Node-02 panics showing the string below.
PANIC; Permanent errors on all HA mailbox disks (while marshalling header) in SKprocess fnmbx_instanceWorker on release 9.5P8 (C)
What has happened in this situation?

正解:

Question No : 9
You have a new VMware vSphere cluster with ESXI 7.0U2 hosts. The hosts are connected to a 4-node AFF A400 NetApp ONTAP9.8 cluster with FC LUNs. You have a requirement to identify and follow I/Os from each VM on the shared FC LUN-backed datastores for troubleshooting purposes.
In this scenario, which VMware feature Is supported by ONTAP software to accomplish this task?

正解:

Question No : 10
A 2-node cluster hosts only NAS data UFs. Allnodes lose access to the cluster network.

image002.png

Referring to the exhibit, which statement is correct?

正解:

Question No : 11
You notice poor performance on your FlexGroup and execute the system node run -node * flexgroup show command for more Information. You notice the "Urge" column has non-zero values.
In this scenario, which statement is true?

正解:

Question No : 12
You have a 2-node NetApp FAS2750 switchless cluster with twenty-four 1.8 TB disks that is experiencing performance issues.
Upon investigation, you discover severaltype B consistency points.

image001.jpg

Referring to the exhibit, which corrective action would address these consistency points?

正解:

Question No : 13
Which two automation methods does NetApp ONTAP Select support? (Choose two.)

正解:

Question No : 14
Your customer mentions that they have accidentally destroyed both rootaggregates in their two-node cluster.
In this scenario, what are two actions that must be performed? (Choose two.)

正解:

Question No : 15
You receive the "Unable to connect to the management gateway server"error when trying to connect to a node management IP.
In this situation, how do you determine whether core dumps are generated for the mgwd user space process?

正解:

 / 2